3. Product Description
Features:
Electrical activation by key-operated push-button or
external transducer.
Communication and control unit (CP communication
box).
Ventilation system with thermostat and fan.
Unlocking function in the event of a power failure when
charging with a type 2 charging plug (Mode 3).
Power measurement with mounting and contacting unit,
optional with smart meter eHC EDL21.
Housing made of sheet steel, electrolytically galvanized,
with base coat and powder coating.
Wired ready for connection.
Mode 3 Charging
Mode 1 Charging
Charging socket type 2
Charging socket
SCHUKO®
RCD sensitive to all
types of current
(type B)
Combined
RCCB/CB (type A)
Auto switch
Load management
x
x
x
x
-
-
-
x
x
x
x
x
-
-
-
x
-
x
x
x
x
-
-
-
-
-
x
x
-
-
x
x
3.1
Name plate
The name plate contains all important device data. The
name plate shown is a pattern.
f Note the name plate on your device. The name plate is
located on the device under the cover.
1
XXXXXXXXX
2
Typ.SN:
In
: xx A
3
A
U
: xxx V ~
4
n
f
: xx Hz
5
n
IEC 61851, DIN IEC/TS 61439-7
6
7
Fig.: 1. Name plate (pattern)
1. Manufacturer
2. Item / serial number
3. Rated current
4. Rated voltage
5. Frequency
6. Standard
7. Barcode
8. Number of phases
9. Protection degree
10. Information
xxxxxxxx.xxxxx
xP+N+
8
IPxx
9
AEVCS
10
EN
5