3.4 Operating modes

The device has various operating modes that can be
changed even during operation.
The availability of the individual operating modes
depends on the configuration of the device.
The following operating modes are possible:
„ "Standalone Autostart"
The device is operated as a stand-alone solution with-
out connection to a Backend-System. An authorisation
is not required.
„ "Standalone with Authorisation"
The device is operated as a stand-alone solution
without connection to a master Backend-System. The
authorisation occurs through RFID cards and an inter-
nal Whitelist.
„ "Standalone Backend-System"
The device is connected to the Backend-System via
OCPP. The device is operated via the Backend-System.
Authorisation is dependent on the Backend-System, for
example with an RFID card, a smartphone app or ad
hoc (e.g. direct payment).
„ "Networked"
For Professional+ (PnC) 22 (T2S) versions only.
Several devices are connected via ethernet to enable
use of local load management and to establish a con-
nection to the Backend-System for all networked
devices.
A detailed description of load management
with application examples can be found on our
website in the download section of the selected
product.
8

3.5 LED information panel

The LED information panel indicates the operating status
of the device. Standby, charging, wait time, and fault(s)
are indicated by four symbols in the colours blue, green,
white, and red.
Symbol
Colour
Lit blue
Standby
The device is ready for use. No
vehicle is connected to the device.
Flashes
Standby: Starting the charging
blue
process
„ Authorisation has occurred.
„ Authorisation has not occurred.
Lit
Charging
green
Charging in progress.
Flashes
Charging: Excess temperature
green
warning
Charging in progress. The device
reduces the charging current to
prevent overheating and deactiva-
tion.
Steady
Wait time
white
„ The charging process was
„ Waiting for authorisation.
Flashes
Wait time: Removing the charging
white
cable
The charging process has finished.
f Remove the charging cable.
Lit red
Fault
or flash-
A fault prevents the vehicle from
ing red
being charged.
Î "9 Troubleshooting"
The colours green and blue can be configured when the
device is commissioned.
Î "6.2.6 Advanced settings"
Operating state
No vehicle is connected to the
device.
A vehicle is connected to the
device.
ended on the device. Wait for
confirmation from the vehicle.