Show/Hide Bookmarks
Connection of the control cables between master and slave
Fig.9-3
EDKVF9383 DE/EN/FR 1.0
Connection of the control cables between master and slave
Routing and connection of flat ribbon cable
1.
By default, the ribbon cable
Drive Board in the master.
2.
Route the ribbon cable from the master to the Drive Board connection in the slave,
inserting the ribbon cable
3.
Plug the ribbon cable plug
Connection and routing of cables with plugs (2 pcs.)
1.
By default, the two cables with plugs (2-pole, 10-pole) are in the master. The two plugs
with the corresponding sockets (2-pole, 10-pole) are in the slave.
2.
Route the 2 cables from the master to the sockets in the slave.
3.
Connect the plugs (2-pole
Close the housings of master and slave.
1.
Close the housings with the covers. Fasten the covers with 4 screws each.
Electrical installation
Master and slave connection
is in the master. The plug
is already attached to the
into the cable ducts
.
into the socket
at the Drive Board in the slave.
, 10-pole
) with the corresponding sockets in the slave.
4
9300VEC028
63