Show/Hide Bookmarks
Incremental encoder at input X9
Incremental encoders with HTL level can only be connected to X9.
Fig.9-20
Assignment of 9-pole Sub-D socket (X9) at the controller
Pin
Signal
Technical data
ƒ Input frequency: 0 - 200 kHz
ƒ Current consumption per channel: 5 mA
EDKVF9383 DE/EN/FR 1.0
Connection of the incremental encoder to input X9
Incremental encoder with HTL-level
Signals at CW rotation
Supply voltage for the incremental encoder
1
2
B
O
Note!
Incremental encoders with HTL level, providing A and B signals only, can be
connected to pin X9/2 (A) and pin X9/9 (B). The inputs A and B (pins X9/3 and
X9/1) must then be supplied with the supply voltage of the incremental
encoder.
Electrical installation
Wiring of feedback system
l = max. 50 m
X9
B
B
1
A
2
A
3
4
GND
5
Z
6
Z
7
8
+
9
–
3
4
5
O
+5 V
GND
X9/1
B
X9/2
A
X9/3
A
0.14 mm
2
X9/6
Z
AWG 26
X9/7
Z
X9/8
–
B
X9/9
X9/4
+5 V
1.0 mm
2
X9/5
GND
AWG 18
A
A
B
B
Z
Z
6
7
8
Z
Z
-
4
9300VEC020
9
B
81