Technical Data
Horizontal Suction pump GFS 401 S
Art. No .................................................................................94627
Service connection ................................... 230V/ 50Hz
Motor output P1 ..................................................400 w
Max. immersion .........................................................7 m
Max. head of delivery ..............................................8 m
Max. delivered quantity .................................7000 l/h
Max. suction ............................................................1 mm
Minimum height for automatic switch-on 30 mm
Maximum suction ..........................................bis 1 mm
Max. water temperature .......................................35°C
Hose connection ................................................... 1 ½" IG
Degree of protection ............................................. IPx8
IPX8
weight ..........................................................................5 kg
Read and understand the opera-
ting instructions before using the
appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specified Conditions Of Use
The pump is solely used for drainage and for pum-
ping into and out of containers in the house, garden,
farm and agriculture and only for water.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Caution! During flat sucking in the automatic
mode, the pump can switch on and off every moment
in case of small areas due to water flowing back from
the pump body.
To drain flooded spaces and provide flat suction,
the pump should therefore essentially work in the
continuous mode (see page 6 pic. 1) and should not
be left unattended.
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
when used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sufficient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
power tool description
1 | Sensor switch
2 | Suction foot
3 | Pump connection
4 | Pump connection angle
5 | Connecting branch for the hose fitted with check valve
6 | Handle
7 | Power supply cable
Requirements for operating staff
The operating staff must carefully read the Opera-
ting Instructions before using the appliance.
Qualification : Apart from the detailed instructions
by a professional, no special qualification is neces-
sary for appliance using.
Minimum age : Persons over 16 years of age can
only work on the appliance. An exception includes
youngsters trained in order to reach knowledge
under supervision of the trainer during occupational
education.
Training : Using the appliance only requires corre-
sponding training by a professional or the Operating
Instructions. No special training is necessary.
The operator is responsible for accidents or risks to
third parties.
Observe to keep out of dangerous zone
ENGLISH
15