Receiver Programming - Aprimatic T3EC Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SW1 - Switch 3:
Pre-fl ashing
ON
Enabled
OFF
Disabled
DIP-SWITCH 3: pre-fl ashing selection. This DIP-SWITCH is used to enable or
disable pre-fl ashing. It can be selected both during opening and closing. If the function
is enabled, before the automation starts opening or closing, the warning light and the
fl asher will be enabled for 3 seconds before the it starts.
SW1 - Switch 4:
Reverse stroke
ON
Enabled
OFF
Disabled
DIP-SWITCH 4: reverse stroke. This DIP-SWITCH is used to enable or disable
the reverse stroke at the end of the closing cycle, a procedure which "discharges"
the automation of any voltage which has accumulated during stopping against the
mechanical limit switch. Do not use with the Area barrier, AT64, AT62 and AT60.
Switch to the OFF position.
SW1 - Switch 5:
1 or 2 motor selection
ON
2 motors (master + slave)
OFF
1 motor
DIP-SWITCH 5: 1 or 2 motor selection. Makes it possible to optimise the
performance of the anti-crush and slowdown controls with an operator that has
1 or 2 motors.
SW1 - Switch 6:
Anti-crush
ON
Enabled
OFF
Disabled
DIP-SWITCH 6: anti-cruh control disabling. In OFF position disables the
anti-crush control.
Information
• The control device has a fi xed operating time of 40 seconds.
• Nearing speed and time are fi xed and allow for a smooth and noiseless movement
toward the limit stops during opening and closing.
ENGLISH

3.6 RECEIVER PROGRAMMING

JP5-8 (ENABLING BUTTON) - Using the jumpers JP5-8, you can select which
receiver output channel and, therefore, which remote control button, will enable the
output signal. This selection is made by closing just one of the jumpers present,
following the scheme indicated below:
Ch4
JP8
Ch3
JP7
OUT RX
Ch2
JP6
Ch1
JP5
JP3-4 (ENABLING BUTTON ROW) - The receivers may be used with 2-4 or
14-button remote controls. If you use it with a 14-button remote control, you can use
the jumpers JP3 and JP4 to defi ne which row of buttons the receiver must respond to,
following the scheme indicated below:
JP3 – JP4 open: row 1 (Buttons 1-4)
JP3 closed: row 2 (Buttons 5-8)
JP4 closed: row 3 (Buttons 9-12)
JP3 – JP4 closed: row 4 (Buttons 13-14)
Information
The receiver may also receive commands from 2- and 4-button remote controls
(TR2 and TR4) but only if JP3 and JP4 are left open (first configuration
above).
JP3
OFF
ON
JP4
OFF
OFF
JP5 – Channel 1 - Button 1
JP6 – Channel 2 - Button 2
JP7 – Channel 3 - Button 3
JP8 – Channel 4 - Button 4
WARNING- Only close one jumper or
you risk breaking the unit !
OFF
ON
ON
ON
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T3sc

Table des Matières