5.5 DELETING A REMOTE CONTROL
1. With the device powered up, press and hold down the delete button SW2: the LED
DL8 lights up and the buzzer BZ1 will sound continuously.
2. Press any button on the remote control you want to delete.
3. The LED DL8 and the buzzer BZ1 will go OFF to indicate that deletion of the
remote control is complete.
• To delete more than one remote control, repeat stage 2 above, holding down
the SW2 button.
• This procedure is useful for deleting remote controls which have been saved by
mistake. A remote control which has been deleted can be saved to the receiver
again by following the procedure described above.
Power supply
Key
Remote control
activation
Buzzer
6. ACCESSORIES
6.1 CA41 MODULE (ONLY FOR T3SC)
The insertion of this module in the unit adds a extra reception channel to the device. The
extra channel makes it possible to control two different devices from the SAME UNIT
AND THE STANDARD 2-BUTTON APRIMATIC REMOTE CONTROL.
6.2 16 KB OR 128 KBITS MEMORY EXPANSION MODULE (ONLY FOR T3SC)
Adding this module to the unit makes it possible to manage up to 1,500 devices.
6.3 PROGRAMMING TOOLS (ONLY FOR T3SC)
Aprimatic devices and remote controls may also be programmed using the following:
• APRITOOL programmer for access control management
• APRICOT-MANAGER access control management software
• Connection base for programming APRIBASE 1 transmitters
6.4 CODED KEYPAD
It is possible to install a coded keypad by connecting the CT3 decoding card to
the K3 connector.
6.5 BADGE READER
It is possible to fi t a badge reader by connecting the LB4 decoding card to the
K3 connector.
6.6 UNICO RECEIVER
Snap on radio receiver module for controlling an Aprimatic control unit and a maximum
of another 3 generic devices (with dedicated optional relay modules).