Production mode (electrolysis menu)

2. The 'Level' sub-menu allows
you to select the Chlorine
production level in g/hour for the
Pro A model and in % production
for the Pro Ls model up to the
max that can be delivered by the
device.
While 'level" is highlighted, press
the up and down arrows to modify
the value, press OK to save.
7.3

Settings (Measures menu)

This menu allows calibration of the devices measuring sensors: the
temperature sensor, and the pH and redox sensors if these options
were added.
In the case that the optional sensors were installed, their set points
(maximum pH and minimum Redox) will need to be set.
Select the "Measures" menu.

7.3.1 Selecting the set points

To select the pH and/or Redox potential set points, choose
the "Set points' sub-menu, followed by the parameter for
which you want to select a set point.
To modify the values, use the Plus/Minus keys. Press OK
to save.
pH regulation: the pH set point is the maximum value that should be surpassed, the generation of
Chlorine causes a slow, gradual rise of the pH. In the event that the pH sensor detects a value higher that
the set point, the device will compensate by injecting acid into the water, until the value measured falls
TRAITEMENT DE L'EAU
1. Select the Electrolysis
menu by highlighting it
(Up/Down arrows) iand
pressing OK.
3. The 'Boost' sub-menu forces
the device on at max production
for 24 hours, subject to the
reservation that the filtration pump
is also running continuously. If the
pump is slaved to the Chlorine
generator, filtration will run for
24 hours despite the filtration
'windows' programmed in 'Auto'
mode in the Filtration menu.
After 24 hours, the device
will return to the production
level selected, and the pump
programming mode will take over.
Deactivate the Redox set point
to allow the device to exceed it
during the 24 hour boost.
4. The 'Cover' sub-menu allows
the production of Chlorine to be
reduced to a set percentage of
the level programmed. If the Level
is 22g/h and Reduction is set to
60%, the device will produce at
0.6 x 22 = 13.2 g/h.
Activate
highlighting
arrows), press Plus/ Minus to
display ON, then use the Plus/
Minus keys to select the required
value and press OK to save.