Aperture for
fastening the eye
to the wall
Hold the template against the wall at the selected installation site, and drill in the 4 locations indicated by
the template using a 5 mm diameter drill bit. Push the bushings into the holes and screw a round head
screw into each bushing leaving it to protrude slightly. Hang the panel on the round head screws using the
suspension eye holes.
!
Do not obstruct the flow of air behind the panel that allows cooling.
!
Do not install the control panel in a cupboard or other location with inadequate ventilation, this could
lead to overheating of the control panel and a risk of fire.
4.3
Electrical wiring
Wire the control panel in as follows;
Connect the cell and the gas sensor to the control panel. NEVER MODIFY OR EXTEND THE CABLES;
TRAITEMENT DE L'EAU
Aperture for
fastening the eye
to the panel
2021/03 - Indice de révision : B Code : 29740