8.3
Installation in a Filtration System
NOTE!
Risk of material breaking.
▶ Attach and connect the module in such a way that vibrations from the system cannot be transferred to the
module.
The module must be attached horizontally on the frame of the filtration system by a holder (e.g. 2 clamps).
It is not adequate to attach the module by the connections only.
→
Check the seals to ensure that they are clean. Only use clean seals.
→
Loosely connect the feed inlet (connector: IN) first, then the concentrate outlet (connector: OUT), and finally
the permeate outlets of the pipe.
→
Ensure that the seals are not displaced when establishing the connections.
→
Check that none of the connections is subject to mechanical stresses.
→
Check that the seals are seated correctly.
→
Alternately tighten the connections.
NOTE!
Damage to the connections.
▶ Do not use force to tighten the connections! Use of excessive force in tightening may cause fractures in the
connections.
14
english
Type T-CUT
Installation