6. USE OF THE ECO HOT WATER
Complete table of parameters
Meaning
Factory-set parameters, do not change
Factory-set parameters, do not change
Functions not available, do not to change
Functions not available, do not to change
Functions not available, do not to change
Functions not available, do not to change
CT probe temperature at beginning of defrosting
CT probe temperature at end of defrosting
Waiting time between two defrostings
Max length of time for defrosting
Functions not available, do not to change
Functions not available, do not to change
Functions not available, do not to change
Temperature set value Heat treatment hot water
Duration of anti-freeze Heat treatment hot water
Hour to begin anti-freeze Heat treatment hot water
Every how many days for anti-freeze Heat treatment hot water
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Factory-set parameters, do not change
Unit of measure for temperature
Factory-set parameters, do not change
Probe used to manage the function of the solar pump
Minimum time of operation of the solar pump
Differential temperature with respect to the SST probe for which the
solar circolatore is activated
Functions not available, do not to change
Functions not available, do not to change
Functions not available, do not to change
Functions not available, do not to change
Functions not available, do not to change
Set temperature for the electric thermal discharge valve VS
Temperature set value for solar pump
Functions not available, do not to change
Set temperature for the heat pump
Functions not available, do not to change
Differential temperature for the heat pump
Setting different temperatures for the electric heater
Set temperature for the electric heater
Time delay of the electric heater
Code
Paragraph
Default
/01
2
/
/02
3
C01
0
C02
5°C
C
C03
-1°C
C04
5°C
d01
-5°C
d02
8°C
d03
90 min
d
d04
8min
d05
3min
d06
0
d07
4°C
g01
60°C
g02
0min
g
g03
0h
g04
7D
E01
1
E02
current
E
E03
240
E04
100
E05
480
H01
1
H02
0
H03
0
H
H04
1
H05
0
H06
1h
H07
0
H99
0
n01
0
n02
3min
n03
5°C
n04
0
n05
00h
n
n06
06h
n07
70°C
n08
10°C
n09
78°C
n10
70°C
n11
0
r01
55°C
r02
45°C
r03
15°C
r
r04
0
r05
55°C
r06
200min
GB
GB
Range
Password
0~4
66
0~3
66
0-No/1-Yes
66
1~10°C
66
-5~5°C
66
-30~30°C
66
-30~0°C
66
2~30°C
66
30~90min
66
1~12min
66
1~10min
66
0~2
66
-10~20°C
66
30~70°C
22
0~90min
22
0~23h
22
7~99D
22
0-Manual/1-Auto
66
-20~20
66
0~500
66
0~500
66
0~500
66
0-No/1-Yes
66
0-No/1-Yes
66
0-Air/1-water
66
1-30min
66
0-No/1-Yes
66
1.0~5.0h
66
0-°C /1-°F
66
0-No/1-Yes
66
0=BTT/1=TTT
66
1-30min
66
0~20°C
66
0-No/1-Yes
66
00~23h
66
00~23h
66
40~90°C
66
1~40°C
66
50~90°C
66
50~90°C
22
0-No/1-Yes
66
10~60°C
22
40~48°C
66
1~20°C
22
0-No/1-Yes
66
30~90°C
66
0~450min
22
63