CUSTOM FUNCTIONS
Cust 11 — Bracketing Sequence
1 – Metered exposure, Underexposure(s), Over-exposure(s)
• A 5 frame bracket in 1/2EV increments is exposed in the following order...
Normal
-0.5EV
+0.5EV
2 – Underexposure(S), Metered exposure, Over-exposure(s)
• A 5 frame bracket in 1/2EV increments is exposed in the following order...
-1.0EV
-0.5EV
Normal
Cust 12 — Rewind Speed
1 – Fast Rewind
Rewinds a 36 exposure roll in approximately 6 seconds.
2 – Slow (silent) Rewind
Rewinds a 36 exposure roll in approximately 9 seconds.
12
-1.0EV
+1.0EV
+0.5EV
+1.0EV
Cust 13 — Meter / Data Panel Illuminator Display Duration
• Selecting longer display durations reduces battery performance.
1 – 5 sec
2 – 10 sec
3 – 30 sec
Cust 14 — AF Area Display
• Press and hold the AF button to display the focus area LEDs.
• Pressing the lens focus hold button does not display the focus area LEDs.
1 - Focus Area LEDs display the active
2 – Focus Area LEDs display the active
3 – Local focus areas display only when the
AF button is pressed.
focus area for 0.1 sec after the
focus locks.
focus area for 0.6 sec after the
focus locks.
13