After Usage
Observe the instructions in the section entitled „Safety".
Never leave spraying agent in the device.
1. Pull up the red piston pressure gauge handle [14] until the tank is depressurized.
2. Lock the piston rod with handle [16].
3. Unscrew the pump [2] from the tank.
4. Dilute the remaining quantity twice in a row with 1/2 liter of water each time and spray
the resulting liquid onto the treated area.
Collect and dispose of the residual liquid according to all applicable laws, requi-
rements and regulations. Observe the instructions of the spray product manu-
facturer!
5. Wipe off the spraying device with a moist cloth.
6. For drying and storing the device, keep the tank [1] and pump [2] separate in a dry
place protected from sunlight and freezing temperatures
Clean the protective equipment and yourself every time after usage.
Care and maintenance
Observe the instructions in the section entitled „Safety".
After using the device 50 times or at least once a year:
Unscrew the pump [2] from the tank.
Dismantle the pump [2].
a) Unlock the piston rod with handle [16].
b) Pull the piston rod with handle [16] out of the cylinder tube up to the stop and turn
it counterclockwise
c) Disconnect the piston rod with handle [16] and the cylinder tube [2].
Grease the diaphragm [18].
Assemble the pump.
a) Push the piston rod with handle [16] into the cylinder tube.
b) Hold the cylinder tube [2] and strongly press in the guiding plug [19] with your
thumb.
c) Pull the piston rod with handle [16] up to the stop down and turn it clockwise
Lock the piston rod with handle [16] and screw the pump [2] into the tank [1].
and clean it under running water.
Grease the O-rings [17] and [22]
AUS
USA
17