After Usage; Care And Maintenance - Mesto FERROX 3565 Mode D'emploi

Masquer les pouces Voir aussi pour FERROX 3565:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
GB
IRL
Pressure regulation cannot be adjusted on the shut-off valve
(Device types 3565, 3585, 3595, 3615)
3. Make certain the optimum spraying pressure is set (→ Table 2) on the pressure gauge [16].
Spraying pressure
1,5 bar (21,8 psi)
2,0 bar (29,0 psi)
3,0 bar (43,5 psi)
Table 2. Dependence: spraying rate and spraying pressure
4. If the spraying pressure decreases more than 0,5 bar (7,3 psi) from the optimum level,
pump some more.
Pressure regulation can be adjusted on the shut-off valve
(Device types 3585G, 3615G)
3. Turn the red „DOSICONTROL" adjusting wheel [20] (Fig. 15) („+" higher pressure,
„–" lower pressure) and adjust the optimum spraying pressure. (→ Table 2, above)
4. Observe the spraying pressure on the pressure gauge [19] (Fig. 15) and readjust if
necessary.
5. If the pressure can no longer be adjusted, pump some more.
+
If liquid mixed with air emerges from the nozzle, the tank is empty.

After usage

Observe the instructions in the section entitled „Safety".
Never leave spraying agent in the device.
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (Fig. 4).
2. Lock the pump handle in place [13]. (Fig. 5).
3. Unscrew the pump [2] from the tank [1]. (Fig. 6).
4. Dilute the remaining quantity twice in a row with 1/2 liter of water each time and spray
the resulting liquid onto the treated area.
Collect and dispose of the residual liquid according to all applicable laws, require-
ments and regulations. Observe the instructions of the spray product manufacturer!
5. Wipe off the device with a moist cloth.
6. For drying and storing the device, keep the tank and pump separate in a dry place
protected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.

Care and maintenance

Observe the instructions in the section entitled „Safety".
After using the device 50 times or at least once a year:
• Disassemble the pump [2] and grease the diaphragm [22]. (Fig. 16 -17).
• Clean the nozzle [23] and insert [24] under flowing water. If necessary use a needle. (Fig. 18).
• Remove the filter [25] from between the shut-off valve [9] and spray line [4] and clean it
under running water. (Fig. 19).
• Grease the O-rings [21] and [27] (Fig. 17 and/or 23)
AUS
USA
Spray quantity for hollow cone nozzle
17
NZ
CDN
0,49 l/min
0,56 l/min
0,69 l/min