EN
After Usage
Observe the instructions in the section entitled "Safety".
Never leave liquid in the device.
1. Pull up the red button on the piston pressure gauge [9] until all excess pressure is
released from the tank (Fig. 5)
2. Lock the piston rod with handle [10]. (Fig. 6)
3. Unscrew the pump [2] from the tank. (Fig. 7)
the resulting liquid onto the treated area.
Collect and dispose of the residual liquid and the tank according to all applicable
Follow the instructions of the spray product manufacturer!
place protected from sunlight and freezing temperatures (Fig. 14).
Clean the protective equipment and yourself every time after usage.
Care and maintenance
Observe the instructions in the section entitled "Safety".
•
Unscrew the pump [2] from the tank. (Fig. 7)
•
Dismantle the pump [2].
a) Unlock the piston rod with handle [10].
b) Pull the piston rod with handle [10] out of the cylinder tube up to the stop and turn it
counterclockwise. (Fig. 15)
c) Disconnect the piston rod with handle [10] and the cylinder tube [2]. (Fig. 15)
•
Grease the diaphragm [13]. (Fig. 16)
•
Assemble the pump.
a) Push the piston rod with handle [10] into the cylinder tube. (Fig. 18)
(Fig. 18)
c) Pull the piston rod with handle [10] up to the stop down and turn it clockwise (Fig. 18)
•
Lock the piston rod with handle [10] and screw the pump [2] into the tank [1].
•
Grease the O-rings [12] and [19]
(Fig. 21)
17
ENGLISH
(Fig. 19)