protected against plaster, paints and solvents which may cause
stains, during finishing or repairing the room.
[C000011] 14. DOOR OPERATING INSTRUCTION
• It is prohibited to obstruct the door movement area.
The door opens vertically upwards. Therefore, no obstacles may
be located in the way of door opening or closing. It is necessary
to ensure that during door movement no persons, especially chil-
dren, or objects are on its way.
Caution! Risk of accident.
• [A000053] It is prohibited to keep using the defective door. It is
particularly forbidden to operate the door, if there is any visible
damage of counterbalancing springs, mounting elements or any
other parts responsible for safe door operation.
• [A000062] Any self-retained repairs of the door are prohibited.
• [B000103] IMPORTANT! Damage due to temperature
difference.
Difference between external (ambient) temperature and internal
(premises) temperature may lead to deformation of the door ele-
ments (bimetallic effect). In this case door operation may result
in its damage.
• [B000007] It is prohibited to keep using the door, if any faults in
its operation, or damage of its components are found. In this case,
immediately put the door out of service, and contact the author-
ized service centre.
[C000012] Check the proper mounting of the door according to As-
sembly and Operating Instruction before its first opening.
The door is mounted properly when its leaf/curtain moves smoothly and its op-
eration is easy.
[B000104] Manually-operated garage doors should be opened and closed
smoothly, without sharp jerks that negatively influence its durability and safe
operation.
[C000035] Opening - the door should be operated manually, using the rel-
evant outside and inside handles/ pulls. Improper operation of the door may
cause accident.
Closing - the door should be closed manually by pushing it vigorously using the
handle. As a result, the door self-locking bolts will latch on proper door frame
elements.
Door bolting (lock) - as standard the door is equipped with a lock, which
may be bolted by removing the key from the lock (if the door does not feature
a drive unit). This allows the handle to turn automatically in its closed position.
In case the door is closed with the bolt, the bolt lever should be left looking
downwards.
Door unbolting (lock) - use the key or blocking bolt:
• from outside - turn the key clockwise, approximately 135° (attention: it is
impossible to remove the key, then),
• from inside - move downwards the blocking bolt, located next to the lock
insert, and simultaneously turn the handle.
[C000088] 15. WICKET DOOR
• Wicket door may only be opened manually by pushing the handle in the di-
rection of door opening. Wicket door should be opened and closed smooth-
ly, without sharp jerks, that negatively influence its durability, operation and
safe usage.
• Wicket door is mounted and adjusted properly, if the leaf moves smoothly,
and its operation is easy.
• Avoid strong striking the door leaf against frame, so called „door banging",
that may result in cracking of paint coating and glazing, in door leaf deforma-
tion, and negatively influence operation of hardware, hinges, gaskets.
• It is prohibited to overload the wicket door leaf, leave the objects within the
door leaf movement area as well as operate the door by force.
[C000089] It is recommended to equip the wicket door with self-closer, which
should only be used for self-closing of the wicket door after its previous manual
opening.
[C000090] Each time before operating the door, it is necessary to make sure
that the wicket door is closed. Wicket door installed in the door with electric
drive must be equipped with limit switch, which prevents the drive switching-on
if the wicket door is open.
[C000091] It is prohibited to apply extra force (other than the self-closer) to fully
close or speed up the wicket door closing, that may result in damage or poor
adjustment of self-closer.
[C000209] It is prohibited to put any objects between the opening
or closing door leaf and frame.
Caution! Risk of accident.
Technical description
IIiO/BS/UniPro/05/2014/ID-91262
Assembly and Operating Instructions – Sectional garage door UniPro
[C000040] 16. THE RANGE OF ENVIRONMENTAL CONDITIONS,
FOR WHICH THE DOOR HAS BEEN DESIGNED
• Resistance to water penetration
• Resistance to wind load
• Thermal resistance
• Air permeability
• Temperature
• Relative humidity
• Electromagnetic fields
(1)
- Refers to manually operated doors. The range of environmental conditions
for the doors with drive is stated in the Assembly and Operating Instruction
of the drive.
[C000050] 17. ROUTINE MAINTENANCE INSTRUCTION
Activities, which may be performed by the Owner after careful
reading of the Instruction supplied with the door:
[A000060] Disconnect the drive power supply during all
maintenance and inspection works.
[C000055] The external door leaf surface shall be cleaned with a sponge and
clean water, or lacquer-cleaning agents available in stores. It is prohibited to use
cleaning agents, which may scratch the door surface, sharp tools, or the nitro
solvent-based cleaning agents, and detergents.
At least once for 6 months carry out the door periodic inspections including:
• Lubricate hinged connections, rollers, springs and guides with e.g. semi-solid
HWS-100 Wurth grease before starting the door and during operation if
needed.
• Do not oil the lock barrel insert. If needed, use the graphite grease.
• During the inspections, check door-to-wall mounting elements, bolts, guiding
rollers. Immediately eliminate any irregularities. It is forbidden to operate the
door, if the irregularities are not eliminated.
• In case of any irregularities or damages of door components, stop using the
door and contact the authorised service centre.
• Check the drive mounting.
[B000029] Dry, clean and very soft, preferably cotton fabrics, must be used
to clean the panes in glazing (windows, glazed aluminium profiles). Non-
scrubbing cleaning agents, e.g. wash-up liquid with neutral pH value may
be used, but it is recommended to perform a trial on a small surface previ-
ously. The pane must be rinsed with water thoroughly before cleaning (it is not
recommended to use high-pressure cleaning appliances) in order to remove
particles of impurities and dust that may cause scratching of pane surface. It is
not recommended to use cleaning agents that contain alcohol or solvents (they
cause permanent tarnishing of pane surface).
[D000231] Clean the stainless steel decoration elements, e.g. with Wurth
cleaning agent for stainless steel, at least two times per month (avoid contact
of the clearing agent with the door leaf).
[C000017] Activities, which may be performed by a Competent
Person having correspondent permissions.
[C000060] The door maintenance should be performed at least once for 12
months. The following activities to be performed during the door routine main-
tenance:
• Check spring tension - for this purpose, open the door leaf by lifting the leaf
to half-open position:
• if the leaf is visibly falling, increase the spring tension by its regulation,
• if the leaf is visibly lifting, decrease the spring tension by its regulation.
• The spring tightening procedure is described in the As-
sembly Recommendations.
• If the above mentioned works are not performed,
there is a risk that the leaf may suddenly drop and
hurt people, or cause damage to objects in its vicinity.
• Check the correct and smooth rotation of rollers during door opening and
closing. If the rollers put resistance or do not rotate at all, check their condi-
tion and rolling surfaces in particular. If necessary, replace entire assemblies.
• Check the mechanical components ensuring safety and correct door opera-
tion. In case of any failures, these must be immediately eliminated, and faulty
components and parts should be repaired or replaced.
• When mounting a drive, block the door bolts in its open position, or install
additional devices for automatic bolting.
• Check the condition of suspension cables and springs.
[C000065] Activities, which should be performed by a Profes-
sional Installer:
Any alterations and modifications to the door should be agreed on with
"WIŚNIOWSKI" Sp. z o.o. S.K.A.
EN
- class 1
- class 2
- 1,07 W/m
K
2
- class 4
- -30 to +50° C
(1)
- max. 80% not condesated
(1)
- not applicable
(1)
5