Connection Leds; Troubleshooting - Interroll MultiControl AI Notice D'utilisation

Masquer les pouces Voir aussi pour MultiControl AI:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection LEDs

LED
Status
Sensor 1
On
Sensor 2
Sensor 3
Sensor 4
I/O 1 I/O 2
On
I/O 3 I/O 4
RD 1 RD 2
On
RD 3 RD 4
Link/act A
On or flashing
(with EtherCAT
Link/act B
bus type)
8.2

Troubleshooting

The MultiControl is a complex system. There are many correlations between all participants in the system. In such a
system, errors are of course likely to occur, either as a result of the conveying processes or the interaction between
the individual components. Not all errors can be displayed in detail and it is not always possible to make a correlation
between the error location and the place at which it is displayed. More detailed error diagnosis is possible via the
PLC.
If you are not able to successfully troubleshoot the problem or eliminate the error, contact Interroll Support and have
the following information to hand:
• Serial number of the affected MultiControl
• Information about the configuration
• Information about the LED displays
• Information about the error codes
Version 2.7 (05/2021) UL
Translation of the original operating manual
Assistance in the event of faults
Meaning
Logical switching status of the displayed sensor: Positive logic configured and
logical "1" (PNP 24 V, NPN 0 V) at the input, or negative logic configured and
logical "0" at the input
Logical switching status of the displayed input/output: Positive logic configured
and logical "1" (PNP 24 V, NPN 0 V) at the input, or negative logic configured
and logical "0" at the input
Target value applied to the displayed RollerDrive
Displayed network connection is OK
59 of 140