Connecting the RollerDrive
RollerDrive AI
1
+24 V/48 V
2
Output: Rotational direction
3
Earth
Seal unused RollerDrive connections with an M8 blind cap to achieve protection rate IP54.
¾
RollerDrive BI
1
+24 V/48 V
2
CAN bus signal CAN High
3
Earth
Seal unused RollerDrive connections with an M8 blind cap to achieve protection rate IP54.
¾
NOTE
Incorrect connected loads can destroy the RollerDrive.
Do not attempt to operate a RollerDrive EC5000 24 V DC at 48 V DC. This will destroy the motor
¾
electronics.
NOTE
Connecting/disconnecting under voltage can destroy the RollerDrive EC5000 with bus interface
The RollerDrive EC5000 BI is not hot-plug-compatible. Disconnect the power supply to connect/disconnect
¾
the RollerDrive EC5000 BI.
Version 2.7 (05/2021) UL
Translation of the original operating manual
Assembly and installation
4
Input: Error
5
Output: Speed
4
CAN bus signal CAN Low
5
Service manufacturer
27 of 140