Start-up and operation
Control Program Settings
Control Program Settings
Program ID
:
I/O Device
Version
: 2017-12-12-11
Control Timer
Timer 1 [ms]
:
0
Timer 2 [ms]
:
0
Timer 3 [ms]
:
0
Timer 4 [ms]
:
0
Selection of control programs
ZPA single release program
ID
Single release 1 zone
Single release 2 zone
Single release 3 zone
Single release 4 zone
Control Timer
Timer 1:
Single release: Transfer communication time
Train release: Time-delayed start of the RollerDrive
Timer 2:
Internal monitoring of the material to be conveyed
Timer 3:
RollerDrive overrun
Timer 4:
Error reset
The functions and default settings for the timers vary depending on the selected control program (see
the description of control programs in the "MultiControl / RollerDrive - Start-up and Programming"
supplement).
Press the "Submit" button to transfer the modified parameters to the MultiControl.
44 of 140
Control Program Settings
ZPA train release program
ID
Train release 1 zone
Train release 2 zone
Train release 3 zone
Train release 4 zone
ZPA module program
ID
ZPA transfer in
ZPA transfer out
ZPA merge
ZPA HPD
HPD semi automatic
Transfer semi automatic
Translation of the original operating manual
Submit
Reset
No ZPA program ID