Assistance in the event of faults
Power
Ready
-
-
-
-
-
-
-
-
-
-
-
-
If several errors occur at the same time, only the error with the highest priority is displayed.
To eliminate the errors, refer to „Troubleshooting" on page 59.
¾
58 of 140
Net run
Fault
-
Flashes x6
-
Flashes x7
-
Flashes x8
-
Flashes x9
-
Flashes x10
-
Flashes x11
Meaning
Voltage error, overvoltage
Temperature in the MultiControl too high.
Overload protection for the brake resistor
active.
Handshake communication interrupted.
See instructions on ZPA and ZPA+
applications.
No connection to the neighbouring
devices. See instructions on ZPA and ZPA+
applications.
A configured neighbouring device has an
error (see ZPA+, "RemoteEmergency" in
the error log)
Translation of the original operating manual
Priority
4
6
7