Start-up and operation
Under voltage error
Supply voltage too low:
Ignore:
Error is not displayed.
Warning:
Error is indicated by fault LED flashing five times.
The conveying process is not interrupted.
Immediate stop:
Error is indicated by fault LED flashing five times.
The conveying process is interrupted.
Motor error
Monitoring of the motors:
Ignore:
Error is not displayed.
Warning:
Error is indicated by fault LED flashing three times.
The LED goes out when the error is no longer present. Further motors connected to the
MultiControl rotate.
Immediate stop:
Error is indicated by fault LED flashing three times.
Further motors connected to the MultiControl stop.
General control error
Monitoring of the control system:
Ignore:
Error is not displayed.
"Immediate stop" and "Normal stop" have the same function.
The control error 1–8 settings have no function.
Press the "Submit" button to transfer the modified parameters to the MultiControl.
Changes only come into effect when the control is switched off/on.