Service – Up-/Download
Download
For download under a different name, please use „Right Click --> Save
As..."-option
Bus Config
:
download
Application Config
:
download
The MultiControl settings can be downloaded via the user interface and saved to a computer. By storing this data, the
settings can be restored when the MultiControl is replaced.
Right-click on the desired file and select "Save as" to save to the connected PC.
¾
Follow the correct sequence for the upload.
• Bus config
• Application config
NOTE
Irreparable damage to the MultiControl due to premature shutdown of the supply voltage
Ensure that the power supply is not interrupted during the entire process of changing the bus type until the
¾
restart is complete. This process takes approx. two minutes.
Version 2.7 (05/2021) UL
Translation of the original operating manual
Up- Download
Upload
To make settings effective, please restart module afterwards!
Bus Config
Application Config
Start-up and operation
:
upload
:
upload