Error State
Error Info
State
: Operational
Active Error
: BusComFail (21)
Last Error
: 00:02:29:756 51 DriveError #2
• Display of the current status of the MultiControl
• Display of the current error
• Display of the most recent error
Error Handling Settings
System Errors
Network Error
: Warning
Over Voltage Error
: Warning
Under Voltage Error : Warning
Motor Error
: Warning
Generl Control Error : Ignore
Sensor Error
: Ignore
Network error
Monitoring of communication between MultiControl and PLC:
Ignore:
Error is not displayed.
Warning:
Error is indicated by fault LED flashing twice.
The conveying process is not interrupted.
Immediate stop:
Error is indicated by fault LED flashing twice.
The conveying process is interrupted.
If the MultiControl is operated without PLC, we recommend the "Ignore" setting.
If the MultiControl is operated with PLC, we recommend the "Immediate stop" setting.
Over voltage error
Supply voltage too high:
Ignore:
Error is not displayed.
Warning:
Error is indicated by fault LED flashing six times.
The conveying process is not interrupted.
Immediate stop:
Error is indicated by fault LED flashing six times.
The conveying process is interrupted.
Version 2.7 (05/2021) UL
Translation of the original operating manual
Error State
Error Handling Settings
Control Errors
Control Error 1
Control Error 2
Control Error 3
Control Error 4
Control Error 5
Control Error 6
Control Error 7
Control Error 8
Start-up and operation
: Ignore
: Ignore
: Ignore
: Ignore
: Ignore
: Ignore
: Ignore
: Ignore
Submit
Reset
45 of 140