Start-up and operation
• IP addresses of neighbouring MultiControls (with ZPA and ZPA+ programs)
IP address upstream: Address of the MultiControl from which articles, trays, materials to be conveyed, products, etc.
are transferred
IP address downstream: Address of the MultiControl to which articles, trays, materials to be conveyed, products,
etc. are delivered
• Definition as to whether the PLC data is in big-endian format (High/Low byte switched)
Press the "Submit" button to transfer the modified parameters to the MultiControl.
NOTE
Irreparable damage to the MultiControl due to premature shutdown of the supply voltage
Ensure that the power supply is not interrupted during the entire process of changing the bus type until the
¾
restart is complete. This process takes approx. two minutes.
Motor Settings
Motor Type
Roller Diameter [mm]
Gearing Ratio
Direction
Normal Speed [m/s]:
Alternate Speed [m/s]:
Acceleration [m/s2]:
Decceleration [m/s2]:
Apply Motor 1 Settings to all
Avoid parallel Motor Start/Stop - ZPA
Start Delay [ms]:
100
Stop Delay [ms]:
100
Brake Chopper Level:
CAUTION
Risk of malfunction!
Change the motor configuration via web browser only when motors are stopped!
¾
36 of 140
Motor 1
EC5000
EC5000
50.0
50.0
49:1
49:1
CW
CCW
CW
1.00
1.00
0.50
0.50
0.00
0.00
0.00
0.00
28 V
26 V
Motor Settings
Motor 2
Motor 3
Disabled
50.0
none
CCW
CW
CCW
1.00
0.50
0.00
0.00
Motor 4
Disabled
50.0
none
CW
CCW
1.00
0.50
0.00
0.00
Submit
Version 2.7 (05/2021) UL
Translation of the original operating manual
Reset