Faber INCA PRO PLUS INPL3019SSNB-B Instructions D'installation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED
TO THE OUTSIDE. For recirculating installations (Figure 1), Charcoal Filters are necessary. Remove
all grease filters and set aside. Attach one charcoal filter to each end of the blower. Each charcoal filter
attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise
to remove (Figure 1A). Replace all grease filters. Recirculating installations also require some duct work
IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED TO THE OUTSIDE. For recirculating
to divert the air out of the top or face or side of the cabinet or custom hood or out of the side / face of
installations (FIGURE 4), Charcoal Filters are necessary. Remove all grease filters and set aside. Attach one charcoal filter to each end
of the blower. Each charcoal filter attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise
the soffit and back into the kitchen. Install at least 15" of vertical run of metal duct (Figure 1) at the air
to remove (FIGURE 4A). Replace all grease filters. Recirculating installations also require some duct work to divert the air out of the top or
outlet. Run the duct vertically and secure it at the relevant opening previously cut out at the top or side
face or side of the cabinet or custom hood or out of the side / face of the soffit and back into the kitchen. Install at least 15" of vertical run of
of the cabinet or soffit. A metal duct cover grille is also recommended. The duct work must not terminate
metal duct (FIGURE 4) at the air outlet. Run the duct vertically and secure it at the relevant opening previously cut out at the top or side of
the cabinet or soffit. A metal duct cover grille is also recommended. The duct work must not terminate inside the cabinet or custom hood.
inside the cabinet or custom hood.
cabinet
or
custom
hood
inca pro plus
PLAN YOUR DUCTWORK
FOR ALL INSTALLATIONS REMOVE ALL WHITE PLASTIC PROTECTIVE COVERING FROM
HOOD, SIDE RAILS, TRIM, GREASE RAILS AND GREASE FILTERS.
To ensure that the blower performs to its highest
possible capacity, ductwork should be as short
and straight as possilbe.
The ductrun should not exceed 35 equivalent
feet if ducted using the required minimum of 6"
round duct. For 10" round ducting with the 1200
cfm internal motor or 900 / 1200 remote blower,
use 55 equivalent feet. Calculate the length of
the ductwork by adding the equivalent feet in
FIGURE 5 for each piece of duct in the system
INSTALLATION WITH IB300 / IB600 INTERNAL BLOWER (300
An example is given in FIGURE 6.
, 600 cfm)
1. Install the Plate B (Figure 2) which came with
45˚ Elbow
the internal blower kit, on top of the rangehood
90˚ Elbow
1. Install the Plate B (FIGURE 8) which came with the internal
90˚ Flat Elbow
blower kit, on top of the rangehood with the hole closer to the back
with the hole closer to the back of the hood. Use 9
Wall Cap
of the hood. Use 9 screws supplied with the blower kit
screws supplied with the blower kit.
FIGURE 5
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
FIGURE 6
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
FIGURE 2
as possible.
FIGURE 8
2. Remove the white plastic covering and install the 4 side trim
pieces to the outside of the hood using (16) part 9b screws, see
the side rail installation in (FIGURE 9).
8
RECIRCULATING INSTALLATIONS
RECIRCULATING INSTALLATIONS
ceiling
duct
work
FOR ALL INSTALLATIONS
REMOVE ALL WHITE PLASTIC PROTECTIVE COVERING FROM HOOD, SIDE RAILS,
TRIM, GREASE RAILS AND GREASE FILTERS
1. Disconnect and move freestanding range from cabinet opening to provide easier access
to upper cabinet or custom hood. Put a thick, protective covering over cooktop, set-in range
or countertop to protect from damage or dirt.
INSTALLATION WITH IB300 / IB600 INTERNAL BLOWER
2. Determine and make all necessary cuts in the wall and/or ceiling for the ductwork. Install
the ductwork before the rangehood.
3.0 feet
3. Determine the proper location for the Power Supply Cable. Use a 1
5.0 feet
this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the
12.0 feet
power until installation is complete.
0.0 feet
4. Choose the knock out hole to remove for installing the power cable. Use a screwdriver
to snap off the knock out covering. (FIGURE 7 shows inside the wiring box and outside)
9.0 feet
10.0 feet
0.0 feet
19.0 feet
B
cabinet
or
custom
hood
duct
work
inca pro plus
FIGURE 4
FIGURE 1
(300, 600 cfm)
2. Remove the white plastic covering and install
the 4 side trim pieces (4-5) to the outside of the
hood using (14) part 9c screws, see the side trim
installation in (Figure 3).
FIGURE 11
5. Attach the hood to the cabinet using (12) 9c. screws to the
9c
cabinet. FIGURE 12
5
FIGURE 3
FIGURE 7
ceiling
FIGURE 1A
FIGURE 4A
MAKE YOUR CUT-OUTS
4
Drill Bit to make
1/4"
4
5
Version 07/11 - Page 7

Publicité

Table des Matières
loading

Table des Matières