Wall Framing For Adequate Support; Preparing The Installation - AVG LOUISIANA AVL-306CS2 Instructions D'installation Et Guide De L'usager

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
INSTALLING THE HOOD MOUNTING BRACKET
For the most efficient airflow exhaust use a straight run or as few elbows as possible.
Vent unit to the outside only.
Two people are required for installation
Remove the range hood from the carton packaging and place on a flat surface for 
assembly.
 ELECTRIC REQUIREMENTS 
CAUTION: THIS APPLIANCE SHOULD BE PROPERLY GROUNDED. 
This hood must be power supplied 120 V, 60 Hz, and connected to an individual, properly 
grounded circuit (3‐prong outlet).
If the electrical supply does not meet above requirements, call a licensed electrician before 
proceeding. 
Route house wiring as close as possible to the installation location, in the ceiling or back wall. 
The hood must  be connected  to  the house wiring in accordance with the local codes and 
norms. 
 
WALL FRAMING FOR ADEQUATE SUPPORT 
This vent hood is heavy. Adequate structure and support must be provided in all types of installations. 
If mounting on dry wall, the hood must be secured to vertical studs in the wall or to a horizontal support. 
 
PREPARING THE INSTALLATION 
 For safety and optimum performance, the vent hood must be installed above the cooking surface at a 
minimum of 26" above an electric range and of 30" above a gas cooking range (unless the instructions 
for installation of the gas hob specify a greater distance, which has to be taken into account.)
 The exhaust air must not be discharged into a chimney which is used for exhausting fumes from other 
appliances burning gas or other fuels.
 Determine  the  exact  location  of  the  vent  hood.  Mark  the 
location.  Find  the  centerline  of  the  cooktop.  Use  a  level  to 
draw a vertical straight pencil line on the wall.
 Plan the route for venting exhaust to the outdoors. Use the 
shortest and straightest duct route possible. Long duct runs, 
elbows  and  transitions  will  reduce  the  performance  of  the 
hood. Use as few of them as possible. Larger ducting may be 
required for longer duct runs.
 Install  a  wall  cap  with  damper  or  roof  cap  at  the  exterior 
opening/wall. Join the wall or roof cap to the ductwork.
 Connect round metal ductwork to cap and work back towards 
the  hood  location.  Use  2"  metal  foil  duct  tape  to  seal  the 
joints.
 
DECORATIVE 
CHIMNEY 
28"  MINIMUM  ABOVE  AN 
ELECTRIC COOKING SURFACE 
30" MINIMUM ABOVE A GAS 
COOKING SURFACE 
16 
ROOF CAP 
6" ROUND
WALL CAP
6" 
ROUND
ELBOW
HOOD 

Publicité

Table des Matières
loading