Before Installing The Hood; Wall Framing For Adequate Support; Preparing The Installation - AVG TEXAS AVT-309CS2 Instructions D'installation Et Guide De L'usager

Hotte murale
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
BEFORE INSTALLING THE HOOD 
For the most efficient airflow exhaust use a straight run or as few elbows as possible.   
Vent unit to the outside only. 
At least two people are required for installation. 
Remove the range hood from the carton packaging and place on a flat surface for assembly. 
 
 
ELECTRIC REQUIREMENTS 
       
CAUTION: THIS APPLIANCE SHOULD BE PROPERLY GROUNDED. 
 
This  hood  must  be  power  supplied  120  V,  60  Hz,  and  connected  to  an  individual,  properly 
grounded circuit (3‐prong outlet). 
If  the  electrical  supply  does  not  meet  above  requirements,  call  a  licensed  electrician  before 
proceeding. 
Route house wiring as close as possible   to the installation location, in the ceiling or back wall. 
The hood must be connected to the house wiring in accordance with the local codes and norms. 
 
WALL FRAMING FOR ADEQUATE SUPPORT 
 
THIS VENT HOOD IS HEAVY.    ADEQUATE STRUCTURE AND SUPPORT MUST BE PROVIDED IN ALL TYPES OF 
INSTALLATION.    IF MOUNTING ON DRY WALL, THE HOOD MUST BE SECURED TO VERTICAL STUDS IN THE 
WALL OR TO A HORIZONTAL SUPPORT.     
 
 
PREPARING THE INSTALLATION 
 The exhaust air must not be discharged into a chimney which is used for exhausting fumes from other 
appliances burning gas or other fuels. 
Determine the exact location of the vent hood. Mark the location. Find the centerline of the cooktop. 
Use a level to draw a vertical straight pencil line on the wall. 
Plan  the  route  for  venting  exhaust  to  the  outdoors.  Use  the  shortest  and  straightest  duct  route 
possible. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few 
of them as possible. Larger ducting may be required for longer duct runs. 
Install a wall cap with damper or roof cap at the exterior opening/wall. Join the wall or roof cap to 
the ductwork.  
Connect round metal ductwork to cap and work back towards the hood location. Use 2" metal foil 
duct tape to seal the joints. 
 
    Option 1:
 
   
        Option 2: 
 
Wall cap 
A MINIMUM OF 28" ABOVE AN 
ELECTRIC COOKING SURFACE AND 
A MINIMUM OF 30" ABOVE A GAS 
COOKING SURFACE IS REQUIRED 
22
 
Roof cap 