7 EasyWare PC software

The EasyWare PC software can also be used independently of CardioSoft
and print tests conducted with EasyOne.
Please note:
Tests conducted only with EasyOne-CS and EasyWare (without CardioSoft
cannot be imported to CardioSoft

7.1 EasyWare's main window

The illustration below shows EasyWare's main window.
From top to bottom, you can see menus, toolbar, list of all records from the PC database and status bar.
The list can be sorted in ascending or descending sequence by record number, type, ID, name, age or
test date by clicking on the corresponding column header.
The following information is available for each record, i.e. for each test conducted:
Symbol
Identification of the status of the record (see below)
No.
Internal record number. This is also displayed in EasyOne when selecting the test.
Type
Type of test conducted
ID
Patient identification number (if entered)
Name
Name of the patient (if entered)
Age
Age of the patient
Test date
Date and time of the test
The symbols below serve to identify the record status.
A red exclamation mark indicates a record that has not yet been synchronized with the
EasyWare PC database, i.e. this record is currently saved only in EasyOne.
A blue database symbol identifies a record that is available in the EasyWare PC database.
A green database symbol indicates a record that has been generated via CardioSoft
available in the EasyWare PC database. Certain operations, for example editing patient
data, are not possible with this type of record.
A red database symbol indicates a record that exists in the PC database but that has been
updated or supplemented in EasyOne. One example is adding a Post test. This record is
synchronized during the next synchronization operation.
An amber sheet indicates a patient record that was generated in EasyWare. This record con-
tains only patient data and no measurement data. This record can be used in EasyOne for
future measurements.
A grey sheet indicates a patient record that was generated via CardioSoft
contains only patient data and no measurement data.
The status bar, i.e. the lower area of the EasyWare main window, shows the serial number of the con-
nected instrument and the current connection status (for example 'Not connected' or 'Device con-
nected' etc.).
TM
. The software is used to view
TM
subsequently.
Page 22
TM
)
TM
and is
TM
. This record