English
Technical Data
This cooker is category II 2 H 3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
(See appliance data badge for test pressures)
Gas
Natural Gas
Propane
Butane
Dimensions
Connections
Gas:
Rp
Ratings
Hotplate
Centre Burner
Large Burners
Right hand front Burner
* NB this is a special non-counterbored jet - not the same as the 95 jet used in the right hand front Natural
gas burner. Gas burner inputs based on Gross Calorific Value
Ovens
Fan element
Top element
Browning Element
Bottom element
Ovens
Energy efficiency class :
on a scale of A (more efficient) to G (less efficient)
Energy consumption based on standard load
Usable volume (litres)
Size
Time to cook standard load
Baking area
Grill
Maximum total electrical load at 230V 7.4kW approximate total including, oven fan etc.
Cooker back, serial number repeater badge below oven door opening.
20mbar
37mbar
29mbar
Overall height
Overall width
Overall depth
Space for fixing
Minimum space above hotplate
/
at rear right-hand side
1
2
Natural Gas
Input
Injector
4.0 kW
133
3.0 kW
120
1.7 kW
95
Left hand Multifunction Oven
2.5kW
1.2kW
1.15kW
1.0kW
2.3kW
Electric
220 - 240V 50Hz
minimum 915mm
1100mm See 'Positioning of Cooker'
670mm (610mm excluding handles)
See 'Positioning of Cooker'
800mm
Electric
220 - 240V 50Hz
L.P. Gas
Bypass
Input
96
4.0 kW (291 g/h)
54
3.0 kW (214 g/h)
39
1.7 kW (121 g/h)
Right hand Fan Oven
Multifunction
B
0.90kWh
62
Medium
41 minutes
1400cm
2
30
maximum 942mm
Injector
Bypass
95*
57
82
40
64
32
2.5kW
Forced air convection
A
0.85kWh
67
Large
38 minutes
1400cm
2