Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Natural Gas at 20mbar
The 95 jet in burner A is counter-bored and is
different to the non- counter-bored 95 jet in the
conversion kit.
Burner
A
95
B
120
C
133
LP Gas - Butane at 28-30 or Propane at 37mbar
Use the non counter-bored 95 jet in the conversion
kit for burner C.
Burner
A
64
B
82
C
95
SERVICING - WARNING
Burner rings
39
original ring
54
original ring
96
original ring
Burner rings
32
original ring
40
original ring
57
Large ring in
conversion kit
Reassembly
LP Gas
Centre burner
Large ring
Screw in the hexagon headed venturi but to make
fitting the outer burners easier do not fully tighten yet.
Save the original brass ring with the removed orifices
and bypass screws.
the centre burner
24
If you are converting to
LP Gas the burner ring in
the centre burner must be
changed for the large ring
in the conversion kit.