Charge acceptance test

General
Charge acceptance test mode is used to determine a battery's ability to accept a charge.
The charge acceptance test takes place as follows:
-
-
A prerequisite for a satisfactory charge acceptance test is compliance with EU standard
EN-50342-1:2006 item 5.4 (battery approx. 50% discharged).
Preparations
To ensure the battery is about 50% discharged, the following preparations can be carried
out immediately before the charge acceptance test:
1
2
3
Start the charge
1
acceptance test
2
3
4
5
charge acceptance testing is conducted automatically for a period of 15 minutes; if the
result is positive, the device will then switch automatically to standard charging mode
and charge the battery
if the result is negative, „Test Fail" appears on the charger's screen and charging of
the battery is halted
Fully charge the battery
Calculate the discharge current:
discharge current =
Charge battery for approx. 5 hours with the calculated discharge current
Select the charge acceptance test mode by pressing the info button
Set the capacity of the battery to be tested using the „up" and „down" buttons
Connect (+) charging terminal to positive pole on battery
(Connect (-) charging terminal to negative pole on the battery, or to vehicle body (e.g.
engine block) in the case of vehicle electrical systems
battery capacity (Ah)