Technical Data - Donnees Techniques - Fcx Usp - 4 Row - 4 Rangs - Us System - AERMEC FCX 24USPO Manuel Technique

Table des Matières

Publicité

1.
TECHNICAL DATA • DONNEES TECHNIQUES - FCX USP - 4 ROW - 4 RANGS - US SYSTEM
TAB 3 A - TECHNICAL DATA FCX USP (4 ROW) • DONNEES TECHNIQUES FCX USP (4 RANGS)
Mod.
FCX USP
j
Heating capacity
Puissance thermique
Water flow • Débit d'eau
j
Water pressure drops
j
Pertes de pression d'eau
Total cooling capacity
f
Puissance frigorifique
Sensible cooling capacity
f
Puissance frigorifique sens.
Water flow • Débit d'eau
f
Water pressure drops
f
Pertes de pression d'eau
Air flow
Débit d'air
Fan number • Nombre de ventilateurs
Sound pressure level
Niveau de pression sonore
Sound power level
Livello potenza sonora
Peak current • Courant de point
Water content • Contenance en eau
4R Coil connections • Raccords batterie 4R
Dimensions
Dimensions
Net weight • Poids net
ELECTRICAL DATA • CARATTERISTIQUE ELETRIQUES
Power supply • Tension d'alimentation = 1~ 120 V 60 Hz
Max. motor power • Puissance max. moteur
Max. input current • Max. courant absorbé
Power supply • Tension d'alimentation = 1~ 277 V 60 Hz
Max. motor power • Puissance max. moteur
Max. input current • Max. courant absorbé
°C= (°F-32)/1.8
°F=(°Cx1.8)+32
Performance of versions with upgraded motor refers to the following
conditions:
nominal air flow
(*) fan at maximum speed
j heating: inlet water = 158°F; inlet air = 68°F; ∆ t water = 50°F
cooling: inlet air = 81°F d.b.; 66°F w.b.; inlet water = 45°F ; ∆
f
t water = 41°F
sound pressure level (weighted A) measured with open port in a
3
room with 3002 ft
and reverberation time of 0.5 seconds.
16 - EN
(4 row • 4 rangs)
max.
[Btu/hr]
[Btu/hr]
med.
min.
[Btu/hr]
[gpm]
[ft wg]
max.
[Btu/hr]
[Btu/hr]
med.
min.
[Btu/hr]
max.
[Btu/hr]
[Btu/hr]
med.
min.
[Btu/hr]
[gpm]
[ft wg]
max.
[cfm]
[cfm]
med.
min.
[cfm]
max.
[dB (A)]
[dB (A)]
med.
min.
[dB (A)]
max. (E)
[dB (A)]
med. (E)
[dB (A)]
min. (E)
[dB (A)]
[A]
[gal]
ø
Height • Hauter
[inch]
Width • Largeur
[inch]
Depth • Profondeur
[inch]
[lbm]
[W]
[A]
[W]
[A]
24
34
44
13490 19979 29370 34493 48837 58340
10929 16564 23667 29917 39275 49247
7513
13148 17759 21311 29029
1.50
2.21
3.26
3.83
1.34
2.68
7.04
7.37
5891
9563
15198 18100 21686 29371
5123
8367
12909 16290 18852 25955
3927
7001
10143 12363 15368 21413
4713
7274
11270 12090 17178 19740
3893
6110
9296
10590 14327 17131
2828
4921
7100
7790
1.31
2.12
3.37
4.01
1
3.01
8.71
11.73
171
265
353
129
206
271
82
153
194
1
2
2
41.5
39.5
42.5
47.5
34.5
32.5
35.5
42.5
22.5
25.5
28.5
33.5
50
48
51
43
41
44
31
34
37
0.75
1.35
1.53
1.08
0.26
0.40
0.50
0.50
3/4"
3/4"
3/4"
17.8
17.8
17.8
17.8
22.1
31.2
39.9
39.9
8.50
8.50
8.50
8.50
29.8
41.9
50.7
50.7
54
97
111
0.25
0.45
0.51
0.36
60
60
70
0.28
0.33
0.35
Les performances sont données aux conditions suivantes:
Débit d'eau nominal.
(*)
vitesse maximum ventilateur
j chauffage: temp. d'entrée de l'eau = 158°F;
temp. d'entrée de l'air = 68°F; ∆ t eau = 50°F.
refroidissement: temp. d'entrée de l'air = 81°F b.s.; 66°F b.h.;
temp. d'entrée de l'eau = 45°F ; ∆ t eau = 41°F.
niveau de pression sonore (pondéré A) mesuré dans un milieu de
3
85m
de volume et avec temps de réverbération de 0.5s.
54
64
84
5024
3.83
0.13
7.37
10.05
11373 13705
4.80
6.51
7.71
8.04
424
541
671
353
424
547
235
306
412
2
3
3
48.5
52.5
42.5
47.5
33.5
42.5
56
57
61
51
51
56
42
42
51
1.44
1.86
9.0
9.0
3/4"
3/4"
3/4"
22.0
22.0
45.2
45.2
8.50
8.50
78.3
78.3
82
97
135
0.48
0.62
-
96
-
-
0.48
-
IFCXUSTN 15.05 cod: 4033750_04

Publicité

Table des Matières
loading

Table des Matières