TECHNICAL DATA AND OPERATING LIMITS

Thermal capacity (maximum) (input water 70°C)
Cooling output (maximum) (input water 7°C)
Power consumed (maximum)
Current consumed (maximum)
Input water temperature (maximum)
Operating pressure (maximum)
Room temperature limits Ta
Relative humidity limits in the room R.H.
Protection rating
Power supply
Performance values refer to the following conditions:
- at the maximum motor speed;
Water temperature
In order to prevent air stratification
in the room, and therefore to achieve
improved mixing, it is advisable not
to supply the fan coil with water at a
Minimum average water temperature
If the fan coil is working in continuous
cooling mode in an environment
where the relative humidity is high,
condensate might form on the air
delivery and on the outside of the
device. This condensate might be
Minimum average water temperature [°C]
Temperature with wet bulb
of the air in the room

ELECTROSTATICALLY PRECHARGED AIR FILTER

5 0
4 0
3 0
2 0
1 0
0
0
HL
[W]
[W]
[W]
[A]
[°C]
[bar]
IP
[V~Hz]
temperature over 65°C.
The use of water at high temperatures
could cause squeaking due to the
different thermal expansions of the
elements (plastic and metal), this does
deposited on any objects underneath
and on the floor.
To avoid condensate on the external
structure of the device while the fan is
functioning, the average temperature
of the water must not be lower than
the limits shown in the table below,
0 , 3
0 , 5
0 , 7
Particle diameter [µm]
11 / 11M
16 / 16M
2010
2910
840
1200
18
32
0,09
0,15
0°C < Ta < 40°C
230V ( ±10% ) ~ 50Hz
- the total input power is determined by adding the input power for the
unit and the input power for the accessories connected and declared
in the corresponding manuals.
not however cause damage to the unit if
the maximum operating temperature is
not exceeded.
that depend on the thermo-hygrometric
conditions of the air in the room.
These limits refer to unit operating with
fan at minimum speed.
Temperature of the air in the room with dry bulb
21
23
15
3
3
17
3
3
19
3
3
21
6
5
23
-
8
1 , 0
2 , 0
IHLPCLJ 1809 - 6887206_04
26 / 26M
36 / 36M
4620
2030
35
0,18
80
8
R.H. < 85%
20
25
27
29
3
3
3
3
3
3
3
3
3
4
3
3
7
6
5
= Aermec HL range filter
= Standard filter for fan coils
5940
2830
42
0,22
31
3
3
3
3
5
23