Type Label; Before Installation - Burkert 0131 Manuel D'utilisation

Masquer les pouces Voir aussi pour 0131:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A
D
P R
A
E
P1 P2
A
B
F
P
4.2 application conditions
Ambient temperature max. +50 °C
Protection class
IP65 in accordance with DIN EN 60529 / IEC
60529 with cable plug, e.g. Bürkert Type 2508
Operating duration
Unless otherwise indicated on the type label,
the solenoid system is suitable for continuous
operation
Important information for functional reliability during continuous
operation: If standstill for a long period at least 1-2 activations
per day are recommended.
Viscosity:
37 mm
/s
2
4.2.2 permitted media
Permitted media depending on body material and sealing material
PVC Version:
Sealing
material
FKM
Oxidizing acids and substances, salt solution
EPDM
Alkalis, alkaline washing and bleaching lyes
Brass Version:
Sealing
material
NBR
Neutral media, technical vacuum
FKM
Per-solutions, hot oils without additives, diesel and
heating oil without additives, detergent solution,
technical vacuum
EPDM
Oil and grease-free liquids, cold and hot water,
technical vacuum
6
5
insTallaTiOn
5.1 safety instructions
Danger!
Risk of injury from high pressure in the equipment!
▶ Before loosening the pipes and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
Warning!
Risk of injury from improper installation!
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
3/2-way valve; in rest position output
A pressurized
3/2-way valve; in rest position,
pressure connection P2 connected
to output A. P1 closed
3/2-way valve; in rest position,
pressure connection P connected to
output B
Permitted media
Permitted media
english
Service life
High switching frequency and high pressures
reduce the service life
4.2.1 permitted temperature
Permitted medium temperature depending on body material and
sealing material
PVC Version:
Sealing material
FKM
EPDM
Brass Version:
Sealing
Version with
material
high power AC/DC
NBR
-10 ... +90 °C
FKM
-10 ... +90 °C
EPDM
-30 ... +90 °C
see description on the type label
1)
english
4.3 conformity
In accordance with the EC Declaration of conformity, Type 0131 is com-
pliant with the EC Directives.
4.4 standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.

4.5 Type label

Orifice
Circuit function
Type
0131 A 10,0 FKM
D16
P N 0 - 3 bar
230V 50 Hz 16 W
00050443
W12MN
Id. Number
Manufacturer code

5.2 Before installation

Installation position: any, actuator preferably upwards.
Procedure:
Check pipelines for dirt and clean.
Install a dirt filter before the valve inlet (≤ 500 µm).
5.3 installation
Insert O-ring
Insert
english
Type 0131
Permitted temperature
-10 ... +50 °C
-10 ... +50 °C
Version without elec-
tronic 50 Hz, 60 Hz
1)
-10 ... +90 °C
-10 ... +130 °C
-30 ... +130 °C
Sealing material
Body material
PV
Connection thread, Operating
pressure
Voltage, Frequency,
Power consumption
Tighten union nut - evenly by
hand only
1)
5
7

Publicité

Table des Matières
loading

Table des Matières