Lenze 8200 motec Instructions De Montage page 128

Masquer les pouces Voir aussi pour 8200 motec:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
Fault detection and elimination
Fault messages
1)
Keypad
PC
Error
61
Communication
ce0
a
fault to AIF
(configurable in
C0126)
62
Communication
ce1
a
fault to CAN−IN1
with Sync control
63
Communication
ce2
a
error to CAN−IN2
64
Communication
ce3
error to CAN−IN1
a
with event or time
control
65
BUS−OFF
ce4
a
(many
communication
faults occurred)
66
CAN Time−Out
ce5
a
(configurable in
C0126)
67
Function module
ce6
a
system bus (CAN)
on FIF has set
"Warning" or
"BUS−OFF"
(configurable in
C0126)
126
Cause
Faulty transmission of control
commands via AIF
CAN−IN1 object receives faulty
data or communication is
interrupted
CAN−IN2 object receives faulty
data or communication is
interrupted
CAN−IN1 object receives faulty
data or communication is
interrupted
Controller has received too
many incorrect telegrams via
the system bus and has been
disconnected
For remote parameter setting
via system bus (C0370):
Slave does not answer.
Communication monitoring
time exceeded.
For operation with application
I/O:
Faulty parameter setting of
parameter set changeover
For operation with module in
FIF:
Internal fault
CAN controller sets "Warning"
or "BUS OFF"
EDK82MV222 DE/EN/FR 8.0
Remedy
Insert the communication module
into the hand terminal
l
Plug−in connection − bus
ó
module
Check FIF
Check transmitter
l
Increase monitoring time under
l
C0357/1 if necessary
Plug−in connection − bus
l
ó
module
Check FIF
Check transmitter
l
Increase monitoring time under
l
C0357/2 if necessary
Plug−in connection − bus
l
ó
module
Check FIF
Check transmitter
l
Increase monitoring time under
l
C0357/3 if necessary
Check whether bus terminator
l
available
l
Check screen contact of the
cables
Check PE connection
l
Check bus load, if necessary,
l
reduce the baud rate
l
Check system bus wiring
Check system bus
l
configuration
In all parameter sets the signal
"parameter set changeover"
(C0410/13, C0410/14) must be
combined with the same source
Contact Lenze
Check whether bus terminator
l
available
Check screen contact of the
l
cables
Check PE connection
l
Check bus load, if necessary,
l
reduce the baud rate
L

Publicité

Table des Matières
loading

Table des Matières