The most important codes for commissioning
Possible settings
Lenze
Selection
ð
9
PAR1
5
Own settings
6
Own settings
7
Own settings
8
Own settings
1
0
Parameter not saved in EEPROM
1
Parameter always saved in EEPROM
3
Own settings saved in EEPROM
EDK82MV222 DE/EN/FR 8.0
Commissioning
Own settings
ð
PAR1
ð
PAR2
ð
PAR3
ð
PAR4
IMPORTANT
You can save your own basic
settings for a controller (e.g.
machine delivery status):
1. Ensure that parameter set 1
is active
2. Controller inhibit
3. Set C0003 = 3,
acknowledge with v
4. Set C0002 = 9,
acknowledge with v, to
save your own basic
settings
5. Set C0003 = 1,
acknowledge with v
6. Enable the controller.
Using this function, PAR1 can
be copied to parameter sets
PAR2 ... PAR4
Restorage of own basic setting
in the selected parameter set
Data loss after mains
disconnection
Active after every mains
l
connection
Cyclic parameter changes
l
via bus module are not
allowed.
The parameter set 1 saved as
own basic setting with C0002
= 9
7