7.

INSTALLATION

7.1.

Safety instructions

DANGER!
Danger of explosion!
The device is a closed system. It must not be removed.
The following safety instructions must be observed:
• The surface of the device may become electrostatically charged.
In potentially explosive areas the surface of the devices may be
cleaned with a damp or an anti-static cloth only.
• Only specified cables and lines may be used.
• The operator must ensure an adequate strain relief.
• Observe the maximum thermal load of the installed cables and
lines.
• The inserted seal must be adjusted to the diameter of the cable
/ line.
The rated cross-section of the cables / line cores must be at
least 0.25 mm².
• Screws for attaching the cover of the terminal box must be
tightened to a torque of 100 Ncm (± 5 %).
12
english
PTB 01 ATEX 2101
Installation
DANGER!
Risk of explosion due to overheating!
In the case of battery assembly observe the following data of the valves:
• Dimension of the valve body: 32 mm x 32 mm x 10 mm.
• Material of the valve body: Brass (MS), stainless steel (VA) or
plastic (PA 6 GV).
WARNING!
Danger – high pressure!
When reaching into the system, there is an acute risk of injury.
• Before dismounting pneumatic lines and valves, turn off the pres-
sure and vent the lines.
• During the installation, make certain the flow direction is correct.
• Observe applicable accident prevention and safety regulations
for pressurized devices.
7.2.

Installation of Type 6013

Any installation position.
Preferably with magnet system face up.
1.
Clean pipelines.
2.
Any installation position
Preferential direction with actuator face up.
3.
Connect dirt trap upstream
Observe direction of flow!