Exit the Sequence Mode
Users can press <ESC> or <SET UP> (PLAY/ENDSEQ) key to exit the
sequence mode after sequence line building is finished. The differences
between these two keys are explained as follows. <SET UP>
(PLAY/ENDSEQ) will remove all serial points behind the current point of a
sequence line, e.g. The sequence line 1 is composed of 7 serial points,
from 001 ~ 007; when you go to the point 005 on the LCD and press
(ENDSEQ), the points 005 , 006 and 007 would be deleted. To exit the
sequence mode with (ENDSEQ), you need to go to the point next to the
last point of a sequence line, i.e. 008 in the above example, and press the
key. In addition, exit of the sequence mode with the key <ESC> will still
keep all serial points of a sequence line.
6.4.2
Setting through Camera OSD Menu
Set Sequence Line
Press and hold the key <CAMERA MENU> to enter the OSD setup menu.
Then go to the page with the Sequence setting item to set up the sequence
lines; for further details, refer to the dome camera's user manual. The OSD
menu shown below is for your reference; it would change subject to
different cameras.
SEQUENCE LINE
SEQUENCE POINT
PRESET POSITION
SPEED
DWELL TIME
RUN SEQUENCE
EXIT
Execute Sequence Function
Move the cursor to the item of RUN SEQUENCE to run the sequential
preset points.
6.5
Auto-Pan
Users are allowed to control the Auto-pan function of dome cameras under the
Camera Control Mode; one auto-pan line can be set through the keyboard.
Please follow the following instructions to manipulate this function.
User's manual VDRPJ10 Version 2.3
SEQUENCE
1
01
001
1
001
ENTER
YES
22