6.4.1

Setting through Keyboard

Set Sequence Line
Up to 8 sequence lines can be set directly via the
(1)
(2)
User's manual VDRPJ10 Version 2.3
Press a number key to set a sequence line, e.g. <1> and then press
<SET SEQ> (see the diagram below) to start to modify parameters of
sequence 1. The LCD display is shown as below
xxx. PST SPD DWELL
[004] [15]
[005]
xxx. Indicates Serial Points of a sequence line (001~032); 001 in this
case
PST Indicates Preset Positions (1~128).
SPD Indicates Speed (1~15).
DWELL Indicates Dwell Time (1~127 seconds).
Each sequence line can be composed of up to 32 preset positions
when setting through the keyboard.
If press <4> <ENTER> for PST, <1> <5> <ENTER> for SPD and <5>
<ENTER> for DWELL, for example, the LCD will display as shown
below.
001. PST SPD DWELL
[004] [15]
[005]
Description: The first preset point for sequence 1 is preset position 4.
The dome camera will stay at that position for 5 seconds and go to the
next point at speed 15.
Follow the above steps to set other sequence lines; press <SETUP>
(PLAY/ENDSEQ) to end the setting when finished.