(3)
Execute Sequence Function
Press a number key to specify a sequence line that you want to execute
and then press <RUN SEQ> (see the illustrations above) to start running
sequential preset points. The LCD will display as shown below.
001 P/T/Z/F/OSD Cam
Running Sequence 1
Insert or Delete Setting
Users can insert or delete one of the serial points from a sequence line
easily. Press the key <AUTO PAN> (STOP/INS) to insert a point into the
sequence line; press the key <CRUISE> (PAUSE/DEL) to remove a point
from this sequence line. See the illustrations below for the keys mentioned
here.
Ex. 1: Insert a Point
Suppose that Sequence Line 1 consists of 5 preset positions: PST 1, 2, 3, 4
and 5, and you intend to insert PST 4 between 1 and 2.
Step 1: Input 1 (Sequence Line 1) and press the key <SET SEQ> to enter
001 P/T/Z/F/OSD Cam
1
User's manual VDRPJ10 Version 2.3
Press ▲ and ▼ keys to scroll up or down all pages. Users can also
press ◄ and ► keys to move the cursor. See the diagram follows.
the sequence setting menu.
20