8.3.

installation

Warning!
risk of injury from improper installation!
Non-observance of the tightening torque is dangerous as the
device may be damaged.
Observe the tightening torque (see "
for diaphragms").
8.3.1.
installation of the Valve Body
Welded bodies
Weld valve body in pipeline system.
Other body versions
Connect body to pipeline.
8.3.2.
installation of the actuator (Welded
Body)
installation for actuator with control function a:
noTiCe!
damage to the diaphragm or the seat contour!
When installing the actuator, ensure that the valve is in open
position.
Control function A
pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
36
Tab. 14: Tightening torques
english
Type 2103
Installation
Lightly cross-tighten the body screws until the diaphragm is
between the body and actuator.
do not tighten the screws yet.
Actuate the diaphragm valve twice.
Without pressurization tighten the body screws to the permitted
tightening torque (see following table "Tab. 14: Tightening
torques for diaphragms").
installation for actuator with control functions B and i:
Lightly cross-tighten the body screws without pressurization until
the diaphragm is between the body and actuator.
do not tighten the screws yet.
1 of the actuator with compressed air
Pressurize pilot air port
(5 bar).
Actuate the diaphragm valve twice.
Tighten the body screws to the permitted tightening torque (see
"Tab. 14: Tightening torques for diaphragms").
Control air connection
CF A, CF B, CF I
Fig. 31:
Pilot air port
1