SW24.W
Restore default values and loading from
memory card
Sub
Description
menu
Loading the default values
Waiting press OK for 5 s to load
the default values.
Note:
DEF
Loading the default values then requires the
travel to be calibrated again, LRNT flashes
on the display until (rapid or advanced)
calibration is done.
Loading the programming from
memory card
Waiting press OK for 5 s to load
the values from memory card."
MEM
Loading from memory card com-
pleted OK.
Loading from memory card error
(e.g. no card).
Control panel protection level settings
(default = OFF)
OFF
No protection
Protection of menus MOT, LRNT, TRV, OUT,
1
IN, LGC, STAT, EXP, LOAD
2
Protection of menu RAD
Protection from IP connection (it is not pos-
3
sible to connect to the control panel from a
smartphone)
Protection of menus MOT, LRNT, TRV, OUT,
4
IN, LGC, STAT, EXP, LOAD and IP connec-
tion
5
Protection of menu RAD and IP connection
6
Complete control panel protection
Protection of all board menus, IP connection
7
available
Note:
The password must be entered in the control panel each
time you wish to access a protected menu. If the pass-
word entered is incorrect access to the menu is denied.
Msg
display
oooo
oooo
DONE
EMEM
EN