Vimar ELVOX SW24.W Guide Rapide Installateur page 22

Masquer les pouces Voir aussi pour ELVOX SW24.W:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
SW24.W
Gate left open (OAB)
On if the gate remains open for a
time longer than that defined by
the open gate alarm logic (L16)
Maintenance (MAN)
Output off when the number of
maintenance signalling manoeu-
vres (MNPS) is reached in the
diagnostics section
Synchronization output, com-
pass type interlock (INB)
Automatically configures input S4
as synchronization input without
any choice by the user.
A2
The control panel consents to the
gate opening only if the other gate
is in the closed position.
Synchronization output, com-
pass type interlock (INP) with
presence signal.
Automatically configures input S4
as synchronization input and S3 as
presence input without any choice
by the user. The control panel
consents to the gate opening only
if the other gate is in the closed
position and the presence input is
occupied.
Auxiliary Radio Output Configu-
ration
Impulsive: the output is active for
1 s following the RAU command
from the remote control
Timed: the output is active for the
RAU
time set in the RAUT parameter
following the RAU command from
the remote control
Bistable: the output works in Step-
Step ON/OFF mode
RAU output timing
1 s (minimum time)
RAUT
600 s (maximum time)
Courtesy light timer
1 s (minimum time)
LCO
300 s (maximum time)
20
SCA output operating mode
Gate closed: off
5
Gate open: on fixed
Gate closed: off
Gate moving: intermittent
Gate open: on fixed
Indeterminate position: intermittent
6
pause of 1 s every 5
Gate closed: off
SCA
Gate opening slow intermittent
Gate open on fixed
Gate closing intermittent
Indeterminate position: intermittent
7
pause of 1s every 5
Gate stopped on fixed
Gate moving off
Gate closed off
Gate moving on fixed
Input configuration
Sub
Description
menu
C1/C2/C3/C4 command input
Step-step (PP)
8
The step-step control:
- with the gate stopped and
closed, opens the gate
- in opening, stops or closes the
gate according to the step-step
logic setting (L10)
(1)
- with the gate stopped after open-
ing, closes the gate
- in closing, stops or opens the
1
gate according to the step-step
logic setting (L10)-with the gate
stopped after closing, opens the
2
gate
Pedestrian (PED)
C(X)
Opens the gate to the pedestrian
3
position
(1)
It acts like a step-step if the com-
1
mand is given with the gate in a
position beyond the pedestrian
600
position
(120)
Open (OPEN)
1
The open command:
300
- with the gate stopped and
closed, opens the gate
- in opening is ignored
- with the gate open, resets the
pause time
- with the gate stopped, opens the
gate
- in closing, opens the gate
EN
(1)
1
2
3
4
5
Values
(default)
1
(C1)
2
(C2)
3
(C3)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sw24.w

Table des Matières