SW24.W
Close (CLS)
The close command:
- with the gate stopped and
closed, is ignored
- in opening, closes the gate
- with the gate stopped, closes the
gate
- in closing is ignored
Timer (TIM)
C(X)
The timer command:
- when closed, opens the gate
and keeps it open as long as the
contact remains closed
- when the contact is released it
closes the gate
Pedestrian Timer (TIMP)
Has the same function as the timer
command but on the pedestrian
position
S1/S2/S3/S4 safety input
Off
Photocell closing (PHC)
The closing photocell:
- with the gate stopped, allows the
gate to open
- in opening does not intervene
- with the gate open, does not al-
low it to close and when released
will reset the pause time
- in closing, reopens the gate im-
mediately
Photocell (PH)
The photocell:
- with the gate stopped, does not
allow the gate to open
- during opening stops the
S(X)
movement and when released
proceeds with opening
- with the gate open, does not al-
low it to close and when released
will reset the pause time
- in closing stops the movement
and when released reopens the
gate
Opening photocell (PHO)
The opening photocell:
- with the gate stopped, allows the
gate to open
- in opening, recloses it completely
- with the gate open, allows it to
close and does not reset the
pause time
- in closing does not intervene
Sensitive edge with NC clean
contact (BAR)
- with the gate stopped, does not
4
(C4)
- in opening disengages
- with the gate open, does not al-
- in closing disengages
8.2 KΩ balanced sensitive edge
(8K2)
5
Same behaviour as the NC sensi-
tive edge
Stop (STP)
- stops the gate
Interrupts the automatic closing
as per the logic stop setting from
6
stop (L12)
S(X)
Photocell closing checked
(PHC)
OFF
As per closing photocell but with
(S3 S4)
check
Photocell checked (PHT)
As per photocell but with check
Photocell opening checked
(PHC)
1
As per opening photocell but with
(S1)
check
NC sensitive edge checked
(BART)
As per KΩ NC sensitive edge but
with check
8.2 KΩ balanced sensitive edge
checked (8K2T)
As per 8.2 KΩ sensitive edge but
with check
Control panel logic settings
Sub
Description
2
menu
(S2)
Automatic closing
L1
Automatic closing off
Automatic closing on
Pause time
1 s (minimum time)
L2
180 s (maximum time)
Pedestrian pause time
1 s (minimum time)
L3
180 s (maximum time)
State on power up
3
Gate in closed position:
The first step-step command
opens the gate.
Gate in open position:
L4
The first step-step command
closes the gate. If automatic clos-
ing is on, after the pause time the
gate closes
EN
allow the gate to open
low it to close and when released
will reset the pause time
4
5
6
7
8
9
10
11
Values
(default)
(ON)
OFF
ON
(30)
1
180
(20)
1
180
(OP)
CL
OP
21