SW24.W
Terminal block functions
Block
Terminal Description
T1
SEC
Secondary transformer
T2
21
Opening motor 1
22
Closing motor 1
MOT
25
Opening motor 2
26
Closing motor 2
Accessory power supply
0
negative
Accessory power supply
PS
1
positive
Accessories positive
2
checked
10
Flashing light negative
11
Flashing light positive
18
Electrical lock negative
19
Electrical lock positive
AUX
0
Accessories negative
Configurable auxiliary
A1
output 1
Configurable auxiliary
A2
output 2
Encoder power supply
+E
positive
Encoder power supply
-E
negative
LSW
E1
Motor 1 encoder signal A
E2
Motor 1 encoder signal B
E5
Motor 2 encoder signal A
E6
Motor 2 encoder signal B
99
Common inputs
C1
Configurable control 1
ACT
C2
Configurable control 2
C3
Configurable control 3
C4
Configurable control 4
99
Common inputs
Configurable safety de-
S1
vice 1
Configurable safety de-
S2
SAF
vice 2
Configurable safety de-
S3
vice 3
Configurable safety de-
S4
vice 4
Using the display
The control panel settings are shown on the display and can
Nominal
be edited using the menu navigation buttons as shown in
data
the following table:
24 Vac
Buttons Function
24 Vdc
Switching on the display
80W
OK
Sub-menu entry
24 Vdc
Confirm value change
80W
Scroll up
▲
Increase parameter value
Scroll down
▼
Reduce parameter value
24 Vdc
Exit the menu
500 mA
Cancel value change and return
ESC
to menu
Switching off the display
24 V DC
▲+▼
Resetting the card
35 W
▲+ OK Opening control
12 Vdc
▼+ OK Closing control
15 VA
Display test (switches on each
ESC +
segment of the display and points
OK
500 mA
individually in sequence)
ESC +
When the board is switched on the
Firmware updating mode starts
OK
PP
Step-step control
12 Vdc
Menu
The control panel programming is organised into menus
and sub-menus used to access and edit the parameters
and logics of the control panel. The control panel is
equipped with the following first-level menus:
Menu
Description
NO
MOT
Motor parameters setup
LRNT
Travel calibration procedure run menu
TRV
Travel parameter settings menu
OUT
Auxiliary output configuration menu
IN
Input configuration menu
LGC
Operating logic settings menu
NC
RAD
Remote control management menu
STAT
Diagnostic and reporting menu
EXP
Expansion board management menu
LAOD Default value restore menu
PASS
Protection level settings menu
All sub-menus are described in the following table:
EN
Pressing
duration
I n s t a n t a -
neous
I n s t a n t a -
neous
I n s t a n t a -
neous
I n s t a n t a -
neous
3 s
1 s
1 s
3 s
3 s
I n s t a n t a -
neous
15