SW24.W
Apartment block
Apartment block function off
Does not close and stop in open-
ing
L5
Does not close and stop in open-
ing and pause
Does not close and stop in open-
ing, pause and closing
Rapid closing
Rapid closing function off
Rapid closing in gate mode:
The control panel starts to count
the clearance time (L7) from when
the closing photocell is released,
when the clearance time expires it
closes again.
Rapid closing in barrier mode:
The control panel starts to count
L6
the clearance time (L7) from
when the closing photocell is
released, and when the clearance
time expires it closes again. If
the closing photocell is occupied
again, it gives a stop command.
When released again it continues
with closing. The closing photocell
returns to normal operating after
complete closure.
Clearance time (adjustable at
intervals of 1 s)
Time after which the gate closes
L7
again if the rapid closing (L6) is on
Minimum clearance time
Maximum clearance time
Pre-flash
Flashing time of the flashing light
before the gate starts to move
L8
Pre-flash disabled
3 s pre-flash
4 s pre-flash
5 s pre-flash
Manned
Manned function off
Step-step command disabled,
remote controls not working. The
control panel accepts only open
L9
and close commands
Emergency manned. In normal
standard operating conditions, with
the safety devices occupied it
works as manned.
22
(OFF)
Step by step
OFF
Step-step command operates in
2 steps:
1
open, close, open...
Step-step command operates in
2
L10
3 steps:
open, stop, close, open...
3
Step-step command operates in
(OFF)
4 steps:
OFF
open, stop, close, stop, open...
Stop from step-step
Automatic closing disabled when a
stop command from step-step
1
L11
is given
Automatic closing not disabled
when a stop command from step-
step is given
Stop from stop
Automatic closing disabled when a
stop command from stop is given
L12
Automatic closing not disabled
when a stop command from stop
2
is given
Hammering
Moves briefly in the opposite direc-
tion to that of its travel to facilitate
the release of the electrical lock
L13
Hammering off
On with gate closed
On with gate closed and open
(2)
On with gate open
Operation in battery
Standard operation
1
Normal operation with flashing light
10
disabled
L14
After a re-open command it stays
(OFF)
open
When the main power supply is cut
OFF
off it opens and remains open
3
Economy
4
Standard operation
5
Economy operation on. With the
(OFF)
gate closed, it switches off the ac-
L15
OFF
cessory power supply on outputs 1
and 2. The outputs are powered
1
again following a new command.
Gate remained open indica-
tor Number of minutes after
which, with the gate partially or
2
totally open, whatever the set
pause time, an alarm signal is
sent (on the display and output
L16
configured
as OAB)
Indicator disabled
Minimum interval
Maximum interval
EN
(4)
2
3
4
(ON)
OFF
ON
(ON)
OFF
ON
(OFF)
OFF
1
2
3
(1)
1
2
3
4
(OFF)
OFF
1
(30)
OFF
3
60