SW24.W
Slowdown distance when clos-
ing motor 1
T34
No slowdown
Slowdown for the whole distance
Slowdown distance when clos-
ing motor 2
T35
No slowdown
Slowdown for the whole distance
Note:
T32, T33, T34, T35 represent the % of travel or total
work time done at slowdown speed
Acceleration time when opening
motor 1
Maximum acceleration (0 s to
T36
reach normal speed)
Minimum acceleration (2.0 s to
reach normal speed)
Acceleration time when opening
motor 2
Maximum acceleration (0 s to
T37
reach normal speed)
Minimum acceleration (2.0 s to
reach normal speed)
Acceleration time when closing
motor 1
Maximum acceleration (0 s to
T38
reach normal speed)
Minimum acceleration (2.0 s to
reach normal speed)
Acceleration time when closing
motor 2
Maximum acceleration (0 s to
T39
reach normal speed)
Minimum acceleration (2.0 s to
reach normal speed)
Note:
T36, T37, T38, T39 are the times during which the
motor accelerates to reach the normal opening
speed (adjustable at intervals of 0.1 s)
Deceleration ramp motor 1
Steep ramp (maximum decelera-
T40
tion)
Low ramp (minimum deceleration)
Deceleration ramp motor 2
Steep ramp (maximum decelera-
T41
tion)
Low ramp (minimum deceleration)
Note:
T40 and T41 are the deceleration ramp between
normal motor speed and slowdown speed.
Auxiliary output configuration
(20)
Sub
Description
0
menu
Electric lock
100
Output off
(20)
Electrical solenoid lock
Electrical drop lock
0
19
Electrical magnetic lock (suction)
100
on in closing
Electrical magnetic lock (suction)
on in opening and closing
Electrical solenoid lock excita-
tion time
(0.5)
(adjustable at intervals of 0.1 s)
19T
0.5 s (minimum time)
0
5.0 s (maximum time)
Terminal A1 output type
2.0
Output off
Gate open warning light (SCA)
(0.5)
Operation as per SCA parameter
setting
0
Auxiliary Radio output (RAU)
Operation as per RAU parameter
2.0
setting
Courtesy light (LCO)
(0.5)
On during leaf movement and for
the amount of time after the leaf
0
A1
stopping set in parameter LCO
Zone light (LZO)
2.0
On during leaf movement
Gate left open (OAB)
(0.5)
On if the gate remains open for a
time longer than that defined by
0
the open gate alarm logic (L16)
Maintenance (MAN)
Output off when the number of
2.0
maintenance signalling manoeu-
vres (MNPS) is reached in the
diagnostics section
Terminal A2 output type
Output off
(30)
Gate open warning light (SCA)
Operation as per SCA parameter
0
setting
Auxiliary Radio output (RAU)
100
Operation as per RAU parameter
(30)
A2
setting
0
Courtesy light (LCO)
On during leaf movement and for
100
the amount of time after the leaf
stopping set in parameter LCO
Zone light (LZO)
On during leaf movement
EN
Values
(default)
(1)
OFF
1
2
3
4
(1.2)
0.5
5.0
(1)
OFF
1
2
3
4
5
6
(2)
OFF
1
2
3
4
19