ELECTRICAL CONNECTION
(Only for model N55 .. 042)
To connect the supply cable:
•
Remove the screws securing the
cover 'A' on the rear of the cooker
(fig. 8.3).
•
Fitted with a 5-pole terminal block,
position the U bolts 'C' onto termi-
nal block 'B' (fig. 8.3) according to
the diagrams in fig. 8.4.
•
Feed the supply cable through the
cable clamp 'D' (fig. 8.3). The sup-
ply cable must be of a suitable size
for the current requirements of the
appliance; see the section "Feeder
cable section".
•
Connect the wires to the terminal
block 'B' as shown in the diagrams
in figure 8.4.
•
Take up any slack in the cable and
secure with the cable clamp 'D'.
•
Replace the cover 'A'.
Fig. 8.3
FEEDER CABLE SECTION
"TYPE H05RR-F"
220-240 V ac 50/60 Hz
220-240 V 3 ac 50/60 Hz
380-415 V 3N ac 50/60 Hz
380-415 V 2N ac 50/60 Hz
(**) – Connection with wall box connection.
– Diversity factor applied
– A diversity factor may be applied to
the total loading of the appliance only
by a suitably qualified person.
220-240 V ac
1 2 3 4 5
380-415 V 3N ac
1 2 3 4 5
L
1
Fig. 8.4
L
N (L
)
PE
1
2
L
L
N
PE
2
3
3 x 4 mm
(**)
2
4 x 2,5 mm
(**)
2
5 x 1,5 mm
(**)
2
4 x 2,5 mm
(**)
2
220-240 V 3 ac
1 2 3 4 5
L
L
L
PE
1
2
3
380-415 V 2N ac
1 2 3 4 5
N
PE
L
L
1
2
29