ELECTRICAL FEEDER CABLE CONNECTION
(only for models N55 .. 340, N55 .. 342, N55 .. 440, N55 .. 442)
The operations must be executed by a qualified technician.
To connect the supply cable:
Remove the screws securing the cover "A" on the rear of the cooker (fig. 8.1).
Feed the supply cable through the cable clamp "C" (fig. 8.1). The supply cable must
be of a suitable size for the current requirements of the appliance; see the section
"Feeder cable specifications".
Connect the wires to the terminal block "B" as shown in the diagram in figure 8.2.
Take up any slack in the cable and secure with the cable clamp "C".
Replace the cover "A".
Note: The earth conductor must be left about 3 cm longer than the others.
FEEDER CABLE SECTION
TYPE H05RR-F
Models N55 .. 340, N55 .. 342:
220 - 240 V ac 50/60 Hz
Model N55 .. 440, N55 .. 442:
220 - 240 V ac 50/60 Hz
(*)
Connection possible with plug and outlet
(**) Connection with wall box connection
B
A
Fig. 8.1
28
3 x 1,5 mm
(*) (**)
2
3 x 2,5 mm
(**)
2
C
Before effecting any intervention on
the electrical parts of the appliance,
the connection to the network must be
interrupted.
220 - 240 V ac
L
N
1
(L
Fig. 8.2
PE
)
2