the flexible pipe is not under tension, twisted, kinked or too tightly bent, neither while
the appliance is in use nor while it is being connected or disconnected.
the flexiple pipe does not exceed 2000 mm in length (or refer to applicable local re-
gulations) and does not come into contact with sharp edges, corners or moving parts.
Use a single flexible pipe only; never connect the cooker with more than one flexible
pipe.
the flexible pipe can easily be inspected along its entire length to check its condition; if
it has an expiry date, it should be replaced before that date.
if using a flexible pipe which is not entirely made of metal, make sure that it does not
come into contact with any part of the cooker with a surface temperature of 70°C or
above (or refer to applicable local regulations).
the hose is not subject to excessive heat by direct exposure to flue products or by
contact with hot surfaces.
the rigid or flexible pipe is replaced if it shows signs of wear or damage.
a gas pressure regulator, in compliance with the applicable local regulations, is instal-
led when connecting to an LPG cylinder.
you inform the customer that the cylinder valve or the supply valve immediately by the
appliance should be closed when the cooker is not in use.
you inform the customer that the rigid or flexible pipe should not be subjected to corro-
sion by acidic cleaning agents.
After connecting the cooker to the gas supply, make sure that you
check that the connections are correctly sealed using a soapy solution, but never a
naked flame.
check whether the injectors are correct for the type of gas being used.
replace the sealing washer on the slightest sign of deformation or imperfection. The
sealing washer is the part which guarantees a good seal in the gas connection.
use two spanners when connecting the rigid or flexible pipe (Fig. 7.3).
Note: if already fitted on the inlet pipe, remove the rubber hose holder
24
Gas connection with rigid or flexible pipe
Inlet pipe
Manifold
male
pipe fitting
Sealing
washer (#)
1/2" G cylindrical
(ISO 228-1) female
Flexible pipe
(not supplied)
1/2" G cylindrical
(ISO 228-1) male
(#) If not already fitted on the inlet pipe,
it is supplied with the appliance in a
separate kit
1/2" G cylindrical
(ISO 228-1) female
Rigid pipe
(not supplied)
Fig. 7.3